The parameters of electromagnetic flowmeter 】 【 specifications
The velocity
15 m/s
precision
0.5%
Fluid conductivity
5 mu s/cm or more
Nominal pressure
DN10 ~ 12
1.6 MPa
DN350 to 24 ")
1.0 MPa
DN700 ~ DN3000
0.6 MPa
The environment temperature
The sensor
25 ℃ ~ 60 ℃
Converter and a body
- 10 ℃ ~ 60 ℃
Lining material and fluid temperature
The lining material
Points in shape
A shape
Ptfe (F4)
100 ℃; 150 ℃ (special order)
70 ℃
F46
100 ℃; 150 ℃ (special order)
70 ℃
PFA
100 ℃; 150 ℃ (special order)
70 ℃
Polyurethane (pu)
80 degrees
70 ℃
Poly (neoprene
80 ℃; 120 ℃ (special order)
70 ℃
Electrode materials
Molybdenum stainless steel; C, B, titanium, tantalum, platinum-iridium alloy, stainless steel coated with tungsten carbide
Connecting flange material
Carbon steel, stainless steel should be customized
Enclosure protection
IP65, IP67, IP68
The power supply mode
220 v AC; 24 v DC; Battery power supply;
Communication methods
RS232. RS485. Standard MODBUS protocol; HART protocol; GPRS